  • noun The root mean square of the electrical current which a device (usually a wire) can carry within a specific environment (including temperature rating, power loss, heat dissipation, etc.) It is measured in amperes, (amps) and is most often used to rate electrical wires and cables.

Etymologies

Sorry, no etymologies found.

Support

Help support Wordnik (and make this page ad-free) by adopting the word ampacity.

Examples

  • In brief, the rules for tapping feeder circuits indicate that a conductor rated 10% of the ampacity of a feeder conductor may be tapped from the feeder, provided it is not greater than 10 ft in length and it terminates in an appropriately sized OCPD.

    CSE - Top Articles 2010

  • The feature is normally used for paralleling cables to feed the full ampacity of the breaker to a load.

    CSE - Top Articles 2010

  • Figure 6 provides an additional example of taps to serve lower-ampacity loads from higher-ampacity circuit breakers, only from a different series of circuit breakers.

    CSE - Top Articles 2010

  • In brief, the rules for tapping feeder circuits indicate that a conductor rated 10% of the ampacity of a feeder conductor may be tapped from the feeder, provided it is not greater than 10 ft in length and it terminates in an appropriately sized OCPD.

    CSE - Top Articles 2010

  • In practice, the 600 A circuit breaker may contain a lower-ampacity trip unit to avoid the necessity to oversize the incoming cable.

    CSE - Top Articles 2010

  • The number and size of loads in an industrial control panel or NEC installation frequently require a circuit breaker 800 A or greater to be used as a main device, with lower-ampacity circuits tapped from it.

    CSE - Top Articles 2010

  • Conductors equal to the full ampacity of the circuit breaker must be extended to the power terminal block

    CSE - Top Articles 2010

  • Figure 3 illustrates a 2,500 A breaker frame with a 1,600 A trip unit (higher ampacity trip units are available to the full-frame rating).

    CSE - Top Articles 2010

  • Figure 6 provides an additional example of taps to serve lower-ampacity loads from higher-ampacity circuit breakers-only from different series of circuit

    CSE - Top Articles 2010

  • The number and size of loads in an industrial control panel or NEC installation frequently require a circuit breaker 800 A or greater to be used as a main device, with lower-ampacity circuits tapped from it.